Encoders

XR115 (SMARTSafe™) Magnetic Encoder

XR115 SMARTSafe 115mm modular incremental quadrature rotary encoders are a breakthrough in hazardous duty encoders.  They are ATEX and UL approved and offer incredibly reliable no-bearing construction!  SMARTSafe encoders can be used in gas and ATEX dust hazardous environments.  Also available:  hollow shaft models (XR45, XR47, XR685), shafted models (XR4F, XR485), and no-bearing modular encoders to fit other flange sizes (XR56, XR67, XR85, XR125, XR850).

For Level 2 applications requiring ATEX/IECEx Zone 2 or 22 or UL Class I, Division 2 (Gas) Groups A,B,C,D use the XR115 directly in your application, with no barrier, isolator or cable gland required.

For Level 1 applications requiring ATEX/IECEx Zone 1 or 21 protection use the XRB1 or XRB2 isolator in your control cabinet which permits the use of intrinsically safe wiring instead of explosion-proof conduit or glands. The XR115 can also be used in UL Class I Div 1 & Zone 0 applications using the XRB2 Isolator.

Unlike the competition, Avtron SMARTSafe encoder systems are protected against short circuits, power-to-output wiring, and output-to-ground faults.

Instead of relying on a tiny optical encoder with weak bearings, install the most rugged encoders available for your drilling or industrial applications.  Vibration, shock, liquids, dust and dirt won't harm SMARTSafe encoders!  Paint booths, draw works, coil tubing rigs...XR115 can keep them all working 24-7-365.

Eliminate the biggest cause of Industrial Encoder failures. Eliminate the bearings with XR115 Hazardous Duty Encoders.

XR115 (SMARTSafe™) Magnetic Encoder

Technical specifications

  • Operating Power

    5-24VDC in/out

  • Current

    In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

  • Output Format

    A Quad B with marker (A,A\; B,B\, Z,Z\)

  • Frequency Range

    0 to 165 KHz

  • Speed

    -

  • Environmental

    IP54

  • Operating Power: (add load and cable drive current as req'd) 
    Level 1 (XRB1): 12-24VDC In, 10.6V Out, 150 mA
    Level 1 (XRB2): 12-24VDC In/Out, 150 mA
    Level 2 Protection: 5-24VDC In/Out, 150mA
  • Maximum Cable Length:
    Level 1: Encoder 500' Isolator 1000'
    Level 2 (5 to 12 VDC in) 500'
    Level 2 (15 to 24 VDC in) 250'
  • Certifications:
    Level 1: ATEX/IECEx Zone 1 & 21 Group IIC
    Level 1: cULus Class I Div 1 and Zone 0 Group A,B,C,D
    Level 2: ATEX/IECEx Zone 2 & 22 Group IIC
    Level 2: cULus Class I Div. 2 Groups A,B,C,D

Latest Application Notes