Encoders

Standard, Modified, Custom & Integration Solutions

XR97 SMARTSafe™ Encoder

XR97 SMARTSafe™ modular sensors enable OEMs to achieve a world first-- hazardous duty encoders with removable electronics, embedded inside their machine.  They are ATEX, IECEx and cULus certified and offer incredibly reliable no-bearing construction!  SMARTSafe sensors can be used in ATEX/IECEx gas and dust and UL gas hazardous environments.  Also available:  hollow shaft models (XR685), shafted models (XR485), no-bearing modular encoders (XR125, XR850), and modular sensors for larger bore applications (XR5, XR12).

For Level 2 applications requiring ATEX/IECEx Zone 2 or 22 or cULus Class I, Division 2, Groups A,B,C,D use the XR97 directly in your application, with no barrier, isolator or cable gland required.

For Level 1 applications requiring ATEX/IECEx Zone 1 or 21 protection use the XRB1 or XRB2 isolator in your control cabinet which permits the use of intrinsically safe wiring instead of explosion-proof conduit or glands. The XR56 can also be used in UL Class I Div 1 & Zone 0 applications using the XRB2 Isolator.

Unlike the competition, Avtron SMARTSafe encoder systems are protected against short circuits, power-to-output wiring, and output-to-ground faults.

Instead of mounting a tiny optical encoder with weak bearings on a wobbling stub shaft, mount XR97 directly on your machine and install the rotor on your main application shaft.  Vibration, shock, liquids, dust and dirt won't harm SMARTSafe encoders!  Paint booths, top drives, draw works, coil tubing rigs...XR97 can keep them all working 24-7-365.

Eliminate the biggest cause of encoder failure--eliminate the bearings with XR97 hazardous duty encoder sensors.

XR97 SMARTSafe™ Encoder

Technical specifications

  • Operating Power

    5-24VDC in/out

  • Current

    In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

  • Output Format

    A Quad B with marker (A,A\; B,B\, Z,Z\)

  • Frequency Range

    0 to 165 KHz

  • Speed

    5000 RPM Max.

  • Environmental

    IP54

  • Operating Power: (add load and cable drive current as req'd)
    Level 1 (XRB1): 12-24VDC In, 10.6V Out, 150 mA
    Level 1 (XRB2): 12-24VDC In/Out, 150 mA
    Level 2 Protection: 5-24VDC In/Out, 150mA
  • Maximum Cable Length:
    Level 1: Encoder 500' Isolator 1000'
    Level 2 (5 to 12 VDC in) 500'
    Level 2 (15 to 24 VDC in) 250'
  • Rotor Position: +/- 0.100” [+/- 2.54mm].
  • Sensor Rotor Gap: 0.04", +0.015"1-0.030" [1.02mm +0.381-0.76mm]
  • Certifications:
    Level 1: ATEX/IECEx Zone 1 & 21 Group IIC
    Level 1: cULus Class I Div 1 and Zone 0 Group A,B,C,D* 
    Level 2: ATEX/IECEx Zone 2 & 22 Group IIC
    Level 2: cULus Class I Div. 2 Groups A,B,C,D

Latest Application Notes