Eksplosionssikre Encodere

Magnetiske Encodere

De modulære inkrementelle kvadratiske roterende encodere er et gennembrud inden for tællere til farlige anvendelser som passe til store aksler. De er godkendt iht. ATEX/IECEx og cULus og tilbyder en ekstremt pålidelig, ikke-bærende konstruktion!

Encoderne kan bruges i ATEX/IECEx gas- og støv- og UL-gasmiljøer. Vi har også verdens første eksplosionssikre encoder med fjernbar elektronik og ingen ekstern barriere!

Certificeringer: ATEX, IECEx & cULus

16 fundne produkter

Explosion Safe Encoders

M6C

M6C

Operating Power

5-24VDC in/out

Current

120mA per output, no load 24VDC

Output Format

A,A–, B,B–; Optional Marker Z,Z–

Frequency Range

0 to 150 KHz

Speed

5000 RPM Max.

Environmental

IP66

XP5

XP5

Operating Power

5-24VDC in/out

Current

400mA max @ 5V, 200mA max @ 12V, 100mA max @ 24V (plus cable load)

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 250 KHz

Speed

6000 RPM Max.

Environmental

IP65

XPH8 (SMARTSafe™)

XPH8 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

400mA max @ 5V, 200mA max @ 12V, 100mA max @ 24V (plus cable load)

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 250 KHz

Speed

6000 RPM Max.

Environmental

IP65

XR115 (SMARTSafe™)

XR115 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54

XR12 (SMARTSafe™) Sensor

XR12 (SMARTSafe™) Sensor

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 165 KHz

Speed

6000 RPM Max.

Environmental

IP67

XR125 (SMARTSafe™)

XR125 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 100mA

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 165 KHz

Speed

5000 RPM Max.

Environmental

IP67

XR45 (SMARTSafe™) Encoder

XR45 (SMARTSafe™) Encoder

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54

XR485 (SMARTSafe™)

XR485 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 100mA

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 165 KHz

Speed

5500 RPM Max.

Environmental

IP66

XR4F (SMARTSafe™)

XR4F (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54

XR5 (SMARTSafe™) Sensor

XR5 (SMARTSafe™) Sensor

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 165 KHz

Speed

6000 RPM Max.

Environmental

IP54 (Electronics)

XR56 (SMARTSafe™)

XR56 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54

XR685 (SMARTSafe™)

XR685 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 100mA

Output Format

A Quad B with marker (A,A–, B,B – , Z,Z – )

Frequency Range

0 to 165 KHz

Speed

4000 RPM Max.

Environmental

IP66

XR85 (SMARTSafe™)

XR85 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54

XR850 (SMARTSafe™)

XR850 (SMARTSafe™)

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

5000 RPM Max.

Environmental

IP54

XR97 SMARTSafe™ Encoder

XR97 SMARTSafe™ Encoder

Operating Power

5-24VDC in/out

Current

In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA

Output Format

A Quad B with marker (A,A\; B,B\, Z,Z\)

Frequency Range

0 to 165 KHz

Speed

5000 RPM Max.

Environmental

IP54

XRB2 Intrinsic Safety Isolator

XRB2 Intrinsic Safety Isolator

Operating Power

12-24 VDC

Current

200mA (w/SMARTSafe™ encoder), max 440mA

Output Format

Incremental A Quad B with marker (A,A–, B,B–, Z,Z– quadrature)

Frequency Range

0 to 165 KHz

Speed

-

Environmental

IP54 (Cabinet mount)

ProductOperating PowerCurrentOutput FormatFrequency RangeSpeedEnvironmentalPDF
M6C 5-24VDC in/out 120mA per output, no load 24VDC A,A–, B,B–; Optional Marker Z,Z– 0 to 150 KHz 5000 RPM Max. IP66 icon
XP5 5-24VDC in/out 400mA max @ 5V, 200mA max @ 12V, 100mA max @ 24V (plus cable load) A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 250 KHz 6000 RPM Max. IP65 icon
XPH8 (SMARTSafe™) 5-24VDC in/out 400mA max @ 5V, 200mA max @ 12V, 100mA max @ 24V (plus cable load) A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 250 KHz 6000 RPM Max. IP65 icon
XR115 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz - IP54 icon
XR12 (SMARTSafe™) Sensor 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 165 KHz 6000 RPM Max. IP67 icon
XR125 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 100mA A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 165 KHz 5000 RPM Max. IP67 icon
XR45 (SMARTSafe™) Encoder 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz - IP54 icon
XR485 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 100mA A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 165 KHz 5500 RPM Max. IP66 icon
XR4F (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz - IP54 icon
XR5 (SMARTSafe™) Sensor 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 165 KHz 6000 RPM Max. IP54 (Electronics) icon
XR56 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz - IP54 icon
XR685 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 100mA A Quad B with marker (A,A–, B,B – , Z,Z – ) 0 to 165 KHz 4000 RPM Max. IP66 icon
XR85 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz - IP54 icon
XR850 (SMARTSafe™) 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz 5000 RPM Max. IP54 icon
XR97 SMARTSafe™ Encoder 5-24VDC in/out In: 10.6V Out: 150mA, In/Out 150mA, In/Out 150mA A Quad B with marker (A,A\; B,B\, Z,Z\) 0 to 165 KHz 5000 RPM Max. IP54 icon
XRB2 Intrinsic Safety Isolator 12-24 VDC 200mA (w/SMARTSafe™ encoder), max 440mA Incremental A Quad B with marker (A,A–, B,B–, Z,Z– quadrature) 0 to 165 KHz - IP54 (Cabinet mount) icon